- What the core looks at before it loads your cells
- Why dead cells hurt every cell in the run
- Whether to send whole cells or nuclei
Single-cell days are stressful: expensive reagents, a booked slot, and cells that don't like waiting. Most failures start at the bench, hours before the instrument. Here's how to walk in calm.
01Where things go wrong
02What the core sees under the microscope
03Why dead cells matter so much
Dead and dying cells leak their RNA into the buffer. That free RNA gets captured with every real cell, adding a background of genes that don't belong. So a few dead cells don't just waste themselves; they blur the whole run.
04Counting you can trust
- Filter, then countRun the suspension through a cell strainer just before counting to remove clumps.
- Use a live/dead stainTrypan blue or a fluorescent stain, so you count live cells, not debris.
- Count twiceIf the two counts differ a lot, mix gently and count again. A wrong count means too few cells recovered, or extra doublets.
05Cells or nuclei?
🔵 Whole cells
- Fresh tissue or blood that dissociates well
- You need surface proteins (CITE-seq)
- You want the most RNA per cell
⚪ Nuclei
- You only have frozen tissue
- Large or fragile cells (neurons, fat, muscle)
- Warm digestion would change expression
- You want chromatin data too (multiome)
Nuclei data look a little different (more intronic reads). That's normal, and pipelines have settings for it.
06Plan the day backwards
A good single-cell run is mostly decided before you reach the instrument. Healthy cells, an honest count, and a plan, and you can walk into the core with confidence.
Doing bulk RNA-seq or DNA sequencing too?
Check your concentration, purity and integrity before you ship, and see what needs fixing. No signup.
Common questions
What viability is "good enough"?
It depends on the core and platform, so ask. Many guidelines aim high (around 90%) and flag samples well below that. If your tissue can't reach it, talk to the core before the day, not after.
Can I fix my samples and run them later?
Some platforms and kits accept fixed cells, which takes the time pressure off the day. Check what your core supports before you choose this route.
Why did I get fewer cells than I loaded?
Every platform recovers only part of the cells loaded, and a wrong count makes it worse. Ask your core what recovery to expect.